Title of article :
Development of 12.5 m2 solar collector panel for solar heating plants
Author/Authors :
Vejen، نويسنده , , N.K. and Furbo، نويسنده , , S. and Shah، نويسنده , , L.J.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Abstract :
Theoretical and experimental investigations have elucidated how different changes in the design of the 12.5 m2 HT flat-plate solar collector from the Danish company ARCON Solvarme A/S influence the solar collector efficiency and the yearly thermal performance. The collector is designed for medium and large solar heating systems. Based on the theoretical findings a prototype of an improved HT solar collector was built and tested side-by-side with the original HT solar collector. The improved HT collector makes use of a changed insulation material, an absorber with improved absorptance and emittance, and a changed antireflection treated glass cover. Calculations based on the measured efficiencies showed that the yearly thermal performance is increased by 23–37% at operation temperatures between 40°C and 80°C when using the improved HT collector. The cost of the collector was however only increased with about 5%.
Keywords :
Solar collector efficiency , Incidence angle modifier , Yearly thermal performance , Glass cover with antireflection surfaces , Absorber with improved absorptance and emittance
Journal title :
Solar Energy Materials and Solar Cells
Journal title :
Solar Energy Materials and Solar Cells