Title of article :
A comparison of conventional and radio frequency tempering of beef meats: Effects on product temperature distribution
Author/Authors :
Farag، نويسنده , , K.W. and Lyng، نويسنده , , J.G. and Morgan، نويسنده , , D.J. and Cronin، نويسنده , , D.A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
8
From page :
488
To page :
495
Abstract :
This study aimed to develop radio frequency (RF) pilot-scale protocols for tempering beef meat blends (4 kg blocks) to achieve average temperatures between −2 and −5 °C. Post-tempering temperature distribution in these blocks was compared to products tempered by conventional methods. The optimum RF power–time combination for tempering lean and 50:50 lean:fat mixtures to the target range was 500 W for 11 min which produced respective means of −3.6 °C (s.d. 1.1) and −3.4 °C (s.d. 1.5). In contrast, 400 W for 11 min was optimum for fat (mean −4.9 °C, s.d. 2.1). This study shows the principal advantages of RF over conventional tempering as an approximate 30 fold tempering time reduction and a greater uniformity of end point temperature distribution under the conditions employed. Furthermore, power consumption was reduced approximately ninefold with RF compared to conventional tempering. More uniform temperature distribution was achieved in samples that were comminuted to a greater extent.
Keywords :
Radio frequency , Tempering , Frozen beef