Title of article :
Iridescence in beef caused by multilayer interference from sarcomere discs
Author/Authors :
Swatland، H. J. نويسنده , , H.J.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Abstract :
Microscope photometry of raw and cooked iliocostalis was used to test the hypothesis that interference colours in beef may originate from reflections from sarcomere discs. Evidence in support of the hypothesis was, firstly, that interference colours were not altered by rotating a polarizer in the illumination pathway, or by rotating a polarizer in the measuring pathway. But when both pathways contained polarizers, iridescence was completely extinguished when the polarizers were crossed. Secondly, the reflectance spectra of interference colours all showed multiple interference peaks, with a major peak possibly originating from the top sarcomere and minor peaks originating from lower sarcomeres. Thirdly, major peaks were strongly dependent on the angle of measurement. Iridescence in beef is quite rare, but reflections from sarcomere discs may be a ubiquitous source of light scattering in meat.
Keywords :
Iridescence , Interference , Sarcomere , Reflectance
Journal title :
Meat Science
Journal title :