Title of article :
A false positive case due to matrix interference in the analysis of ronidazole residues in muscle tissue using LC–MS/MS
Author/Authors :
Kumar، نويسنده , , Praveen and Rْbies، نويسنده , , Antoni and Centrich، نويسنده , , Francesc and Companyَ، نويسنده , , Ramon، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
6
From page :
214
To page :
219
Abstract :
In contrast with the information of the inspection body concerning the use of ronidazole, several non compliant muscle samples were detected using a liquid chromatography–tandem mass spectrometry (LC–MS/MS) method in accordance with confirmation criteria of Decision 2002/657/EC. This led to the suspicion that non compliance could be due to false positive results. In this context, a liquid chromatography–high resolution mass spectrometry (LC–HRMS) method was developed and sample extracts were re-analyzed, resolving the co eluting isobaric interfering peak, which also has an interfering product ion with the transition product (m/z 201 > 140).
Keywords :
Ronidazole , Muscle , High resolution mass spectrometry , Quadrupole–Orbitrap , False positive case