Title of article :
A statistical and experimental investigation into the accuracy of capacity reduction factor for cold-formed steel shear walls with steel sheathing
Author/Authors :
Shakibanasab، نويسنده , , Amir and Attari، نويسنده , , Nader K.A. and Salari، نويسنده , , Mehdi، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
11
From page :
56
To page :
66
Abstract :
Buildings constructed of cold-formed steel members are increasingly used in many countries. In recent years, cold-formed steel shear walls with steel sheathing were introduced as lateral force resisting systems. Design provisions of these structures require that the shear strength of shear walls with a height to width aspect ratio (h/w) greater than 2:1 be reduced by the factor 2w/h for satisfying allowable story drift limit. In this research, the accuracy of the factor is investigated using the results of previous tests and the tests performed by the researcher. Results show that the reduction factor (2w/h) is conservative. Thus, a relation is proposed for the reduction factor.
Keywords :
light steel frame , steel shear wall , Reduction factor , Cold-formed steel frame , Steel sheathing
Journal title :
Thin-Walled Structures
Serial Year :
2014
Journal title :
Thin-Walled Structures
Record number :
1494123
Link To Document :
بازگشت