Title of article :
Reduction of wind uplift of a solar collector model
Author/Authors :
Chung، نويسنده , , K. and Chang، نويسنده , , K. and Liu، نويسنده , , Y.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
13
From page :
1294
To page :
1306
Abstract :
Due to the geographical location of Taiwan, solar water heaters on the roof of buildings are frequently subjected to the impact of severe typhoons. An experimental study of a scaled commercial system was conducted to investigate the mean surface pressure distributions and uplift force at different speeds. To reduce the possible damage due to strong wind uplift, one approach is to lift the model and the other is to install a guide plate. It is found that the wind uplift is reduced effectively with a guide plate normal to the wind direction. Effects of the incremental height of model are less significant in reducing the uplift force. Reynolds number independence for the present test configuration is also observed.
Keywords :
Wind uplift , Guide plate , solar water heater
Journal title :
Journal of Wind Engineering and Industrial Aerodynamics
Serial Year :
2008
Journal title :
Journal of Wind Engineering and Industrial Aerodynamics
Record number :
1498439
Link To Document :
بازگشت