Title of article :
Pressure and flow field investigation of interference effects on external pressures between high-rise buildings
Author/Authors :
Hui، نويسنده , , Y. and Tamura، نويسنده , , Y. and Yoshida، نويسنده , , A. and Kikuchi، نويسنده , , H.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
12
From page :
150
To page :
161
Abstract :
Pressure tests and Particle Image Velocimetry (PIV) tests were conducted to investigate interference effects between two high-rise buildings. Buildings with the same height but different shapes, rectangular and square in plan, were adopted. Pressure test results show that the largest minimum peak pressure on a building under interference effects can be 50% larger than those on an isolated building. PIV tests were used to describe and explain the interference effects from the flow field point of view. The results show that the specific flow pattern with an interfering building may lead to enlargement of the negative peak pressure on the principal building. The interfering building can also reduce the negative peak pressure on the principal building by affecting the formation of a separated shear layer at its leading edge.
Keywords :
Flow field , PIV test , High-rise Building , Interference effects , External pressure
Journal title :
Journal of Wind Engineering and Industrial Aerodynamics
Serial Year :
2013
Journal title :
Journal of Wind Engineering and Industrial Aerodynamics
Record number :
1499588