Abstract :
The large-scale production of recombinant monoclonal antibodies demands economical purification processes with high throughputs. The potential for ion-exchange membrane adsorbers to replace traditional ion-exchange columns was evaluated. Breakthrough capacities of commercially available cation-exchange membranes were determined as a function of flow-rate and layer number. Due to economic and process restrictions, cation-exchange membranes may not currently be advantageous for process-scale antibody purification in a bind and elute mode. However, anion-exchange membranes in a flow-through mode may provide a reasonable alternative to columns for the removal of low levels of impurities such as DNA, host cell protein, and virus.