Title of article :
Ion chromatographic determination of lithium at trace level concentrations: Application to a tracer experiment in a high-mountain lake
Author/Authors :
By U. NICKUS، نويسنده , , Ulrike and Thies، نويسنده , , Hansjِrg and Stemplinger، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
4
From page :
201
To page :
204
Abstract :
The water residence time of a high-mountain seepage lake in the Austrian Alps was derived from the flushing rate of a tracer substance. A diluted lithium chloride solution was injected into the lake during holomictic conditions in order to favour the homogeneous distribution of the tracer. The exponential decline of the mass of lithium in the lake revealed a water residence time of 1.5 to 3 months for summer and almost no lake water exchange during winter. Lithium concentrations ranged from background values of 0.06 μg l−1 to about 3 μg l−1 immediately after the tracer injection. Lake water samples were analyzed with ion-exchange chromatography using a Dionex device with a CS 12A separation column. The method detection limit determined according to the definition of the US Envirinmental Protection Agency amounted to 0.009 μg l−1.
Keywords :
lithium chloride , Metal cations
Journal title :
Journal of Chromatography A
Serial Year :
2001
Journal title :
Journal of Chromatography A
Record number :
1507979
Link To Document :
بازگشت