Title of article :
Retrospective identification of chemical warfare agents by high-temperature automatic thermal desorption–gas chromatography–mass spectrometry
Author/Authors :
Carrick، نويسنده , , Wendy A. and Cooper، نويسنده , , David B. and Muir، نويسنده , , Bob، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
9
From page :
241
To page :
249
Abstract :
An automated thermal desorption (ATD)–gas chromatography–mass spectrometry method was developed for the analysis of selected chemical warfare (CW) agents. Suitable methods were developed for analytes of high volatility to low volatility. The less volatile CW agents required the purchase and installation of a high-temperature valve upgrade kit allowing valve temperatures of up to 260°C to be reached. The limit of detection was 50 ng on the tube for most CW agents in full scan. Chloropicrin exhibited some temperature dependence, with detection limits improving as ATD temperatures were decreased below 150°C. A sample storage trial was undertaken to establish the most suitable storage environment for CW agents adsorbed onto Tenax TA. Temperature and time of storage were found to influence recovery of analytes with best recoveries being observed after 1 day storage in a freezer (−12°C). This method was evaluated during a trial of procedures for sampling and identification of chemical agents at Porton Down, UK. Sulfur mustard was detected downwind of a simulated exploded munition.
Keywords :
organophosphorus compounds
Journal title :
Journal of Chromatography A
Serial Year :
2001
Journal title :
Journal of Chromatography A
Record number :
1508282
Link To Document :
بازگشت