Title of article :
Ring-opening metathesis polymerization-derived monolithic capillary columns for high-performance liquid chromatography: Downscaling and application in medical research
Author/Authors :
Sinner، نويسنده , , Frank M. and Gatschelhofer، نويسنده , , Christina and Mautner، نويسنده , , Agnes and Magnes، نويسنده , , Christoph and Buchmeiser، نويسنده , , Michael R. and Pieber، نويسنده , , Thomas R.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Abstract :
Monolithic capillary columns were prepared via ring-opening metathesis polymerization (ROMP) using norborn-2-ene (NBE) and 1, 4, 4a, 5, 8, 8a-hexahydro-1, 4, 5, 8-exo,endo-dimethanonaphthalene (DMN-H6) as monomers. The monolithic polymer was copolymerized with Grubbs-type initiator RuCl2(PCy3)2(CHPh) and a suitable porogenic system within the confines of fused silica capillaries of different inner diameter (I.D.). The first part of the study focused on batch-to-batch reproducibility of ROMP-derived capillary monoliths. Capillary monoliths of 200 μm I.D. showed good reproducibility in terms of retention times, with relative standard deviations (RSD) of 1.9% for proteins and 2.2% for peptides. However, the separately synthesized capillary monoliths revealed pronounced variation in back pressure with RSD values of up to 31%. These variations were considerably reduced by cooling of the capillaries during polymerization. Using this optimized preparation procedure capillary monoliths of 100 and 50 μm I.D. were synthesized and the effects of scaling down the column I.D. on the morphology and on the reproducibility of the polymerization process were investigated. In the second part, the applicability of ROMP-derived capillary monoliths to a separation problem common in medical research was assessed. A 200 μm I.D. monolithic column demonstrated excellent separation behavior for insulin and various insulin analogs, showing equivalent separation performance to Vydac C4 and Zorbax C3-based stationary phases. Moreover, the high permeability of monoliths enabled chromatographic separations at higher flow rates, which shortened analysis time to about one third. For the analysis of insulin in human biofluid samples, enhanced sensitivity was achieved by using a 50 μm I.D. ROMP-derived monolith.
Keywords :
Proteins , Insulin , Peptides , monolith , Capillary columns , Metathesis polymerization , High-Performance Liquid Chromatography (HPLC)
Journal title :
Journal of Chromatography A
Journal title :
Journal of Chromatography A