Title of article :
Evaluation of monolithic packed 96-tips and liquid chromatography–tandem mass spectrometry for extraction and quantification of pindolol and metoprolol in human plasma samples
Author/Authors :
Abdel-Rehim، نويسنده , , Mohamed and Persson، نويسنده , , Christina and Altun، نويسنده , , Zeki and Blomberg، نويسنده , , Lars، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Abstract :
96-well pipette tips with a chemically bonded monolithic methacrylate sorbent plug were used for solid-phase extraction (SPE) of pindolol and metoprolol in human plasma samples. The sorbent plug was formed by in situ polymerization. Monolithic packed 96-tips are a tool for miniaturized, solid-phase extraction. Using such packed 96-tips, a 96-well plate could be handled in about 2 min. The key aspect of the monolithic phase is that monolithic material can provide both relatively good binding capacity and relatively low backpressure properties. The validation of the methodology showed that the accuracy values of quality-control samples were between 101% and 103% for metoprolol, while between 94% and 114% for pindolol. The precision ranged from 4% to 15%. The standard calibration curves were obtained within the concentration range 5–5000 nM in plasma samples. The coefficients of determination (R2) for plasma samples were ≥0.99. Our prepared polymer based monolithic packed 96-tips were compared with commercial silica based 96-tips and protein precipitation.
Keywords :
Pindolol and metoprolol , Packed 96-tips , Methacrylate monolith , LC/MS/MS , Automated sample preparation , Plasma samples
Journal title :
Journal of Chromatography A
Journal title :
Journal of Chromatography A