Title of article :
Determination of priority carcinogenic polycyclic aromatic hydrocarbons in wastewater and surface water by coacervative extraction and liquid chromatography–fluorimetry
Author/Authors :
Ballesteros-Gَmez، نويسنده , , Ana and Rubio، نويسنده , , Soledad and Pérez-Bendito، نويسنده , , Dolores، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
9
From page :
168
To page :
176
Abstract :
The US Environmental Protection Agency (EPA) and the European Union (EU) have set restrictive limits for priority carcinogenic polycyclic aromatic hydrocarbons (CPAHs) in surface waters (EPA 3.8 ng L−1and EU 2–100 ng L−1) in order to protect aquatic life and human health. Currently, methods meeting these sensitivity criteria are not suitable for routine analysis of CPAHs. Here, we present a simple, rapid and low-cost method for the routine monitorization of these pollutants in aquatic environments based on their extraction with coacervates of decanoic acid reverse micelles in the nano- and microscale, and determination by liquid chromatography–fluorimetry (LC–FL). The method involves the stirring of filtered aqueous samples (36 mL) with 4 mL of THF containing 70 mg of decanoic acid for 5 min, its centrifugation for 10 min and the analysis of 20 μL of the resulting coacervate containing the CPAHs by LC/FL. The method is robust, the extractions being independent on salt concentration (up to 1 M), temperature (up to 60 °C) and pH (below 4). Besides, the coacervate prevents the CPAHs from adsorption onto the surface of containers during sample storage. No clean-up steps are necessary and the method is matrix-independent. The quantification and detection limits of the method ranged between 0.4 and 3.5 ng L−1 and 0.1 and 1 ng L−1, respectively, for the seven priority CPAHs. The method has been successfully applied to the determination of these pollutants in raw and treated sewage from three mechanical–biological treatment plants, two rivers and a reservoir with frequent motorized recreational craft activities, all of them located in the South of Spain. Recoveries for spiked samples in the range 2–30 ng L−1 were between 88 and 95% with relative standard deviations from 1 to 7%. CPAHs were present in wastewater influents at concentrations in the range 3.9–37 ng L−1, while the treatment at the WWTPs studied reduced their concentration in their respective effluents in a percentage near 100%. Three CPAHs were present at quantifiable levels in Guadajoz river (1.8–6.6 ng L−1) and six in La Breña reservoir (1.39–4.8 ng L−1).
Keywords :
Coacervative extraction , Liquid–liquid extraction , Priority carcinogenic polycyclic aromatic hydrocarbons , Reverse micelles , fluorescence detection , Environmental analysis , Liquid chromatography
Journal title :
Journal of Chromatography A
Serial Year :
2008
Journal title :
Journal of Chromatography A
Record number :
1511147
Link To Document :
بازگشت