Title of article
Preparative size-exclusion chromatography for purification and characterization of colloidal quantum dots bound by chromophore-labeled polymers and low-molecular-weight chromophores
Author/Authors
Wang، نويسنده , , Mingfeng and Bardajee، نويسنده , , Ghasem Rezanejade and Kumar، نويسنده , , Sandeep and Nitz، نويسنده , , Mark and Scholes، نويسنده , , Gregory D. and Winnik، نويسنده , , Mitchell A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
9
From page
5011
To page
5019
Abstract
We explore the use of preparative size-exclusion chromatography (SEC) and high-performance liquid chromatography (HPLC) to purify quantum dots (QDs) after surface modification. In one example, in which Bio-Beads (S-X1) were used as the packing material for the preparative SEC column, CdSe QDs treated with a functional coumarin dye could be separated from the excess free dye by using tetrahydrofuran (THF) as the mobile phase. This column was unable to separate polymer-coated QDs from free polymer (M ∼ 8000) because of the relatively low cutoff mass of the column. Here a preparative HPLC column packed with TOYOPEARL gel allowed the effective separation of polymer-bound QDs from the excess free polymer by using N-methyl-2-pyrrolidinone (NMP) as the mobile phase. When other solvents such as absolute ethanol, acetonitrile, THF, and THF–triethylamine mixtures were used as the eluent, QDs stuck to the column. While NMP was an effective medium to remove excess free polymer from the QDs, it was difficult to transfer the purified QDs to more volatile solvents and maintain colloidal stability.
Keywords
High-performance liquid chromatography , size-exclusion chromatography , Polymers , Quantum dots , chromophores
Journal title
Journal of Chromatography A
Serial Year
2009
Journal title
Journal of Chromatography A
Record number
1512125
Link To Document