Title of article :
Erratum to “Solid-phase extraction-gas chromatography and solid-phase extraction-gas chromatography–mass spectrometry determination of corrosion inhibiting long-chain primary alkyl amines in chemical treatment of boiler water in water-steam systems of pow
Author/Authors :
Kusch، نويسنده , , Peter and Knupp، نويسنده , , Gerd and Hergarten، نويسنده , , Marcus and Kozupa، نويسنده , , Marian and Majchrzak، نويسنده , , Maria، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
1
From page :
6671
To page :
6671
Abstract :
Heat due to viscous friction is generated in chromatographic columns. When these columns are operated at high flow rates, under a high inlet pressure, this heat causes the formation of significant axial and radial temperature gradients. Consequently, these columns become heterogeneous and several physico-chemical parameters, including the retention factors and the parameters of the mass transfer kinetics of analytes are no longer constant along and across the columns. A robust modeling of the distributions of the physico-chemical parameters allows the analysis of the impact of the heat generated on column performance. We developed a new model of the coupled heat and mass transfers in chromatographic columns, calculated the axial and radial temperature distributions in a column, and derived the distributions of the viscosity and the density of the mobile phase, hence of the axial and radial mobile phase velocities. The coupling of the mass and the heat balances in chromatographic columns was used to model the migration of a compound band under linear conditions. This process yielded the elution band profiles of analytes, hence the column efficiency under two different sets of experimental conditions: (1) the column is operated under natural convection conditions; (2) the column is dipped in a stream of thermostated fluid. The calculated results show that the column efficiency is remarkably lower in the second than in the first case. The inconvenience of maintaining constant the temperature of the column wall (case 2) is that retention factors and mobile phase velocities vary much more significantly across the column than if the column is kept under natural convection conditions (case 1).
Keywords :
GC-FID/NPD , GC/MS , Primary long-chain alkyl amines , Corrosion inhibitors
Journal title :
Journal of Chromatography A
Serial Year :
2009
Journal title :
Journal of Chromatography A
Record number :
1512340
Link To Document :
بازگشت