• Title of article

    Fast chromatographic method for the determination of dyes in beverages by using high performance liquid chromatography—Diode array detection data and second order algorithms

  • Author/Authors

    Culzoni، نويسنده , , Marيa J. and Schenone، نويسنده , , Agustina V. and Llamas، نويسنده , , Natalia E. and Garrido، نويسنده , , Mariano and Di Nezio، نويسنده , , Maria S. and Fernلndez Band، نويسنده , , Beatriz S. and Goicoechea، نويسنده , , Héctor C.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    8
  • From page
    7063
  • To page
    7070
  • Abstract
    A fast chromatographic methodology is presented for the analysis of three synthetic dyes in non-alcoholic beverages: amaranth (E123), sunset yellow FCF (E110) and tartrazine (E102). Seven soft drinks (purchased from a local supermarket) were homogenized, filtered and injected into the chromatographic system. Second order data were obtained by a rapid LC separation and DAD detection. A comparative study of the performance of two second order algorithms (MCR-ALS and U-PLS/RBL) applied to model the data, is presented. Interestingly, the data present time shift between different chromatograms and cannot be conveniently corrected to determine the above-mentioned dyes in beverage samples. This fact originates the lack of trilinearity that cannot be conveniently pre-processed and can hardly be modelled by using U-PLS/RBL algorithm. On the contrary, MCR-ALS has shown to be an excellent tool for modelling this kind of data allowing to reach acceptable figures of merit. Recovery values ranged between 97% and 105% when analyzing artificial and real samples were indicative of the good performance of the method. In contrast with the complete separation, which consumes 10 mL of methanol and 3 mL of 0.08 mol L−1 ammonium acetate, the proposed fast chromatography method requires only 0.46 mL of methanol and 1.54 mL of 0.08 mol L−1 ammonium acetate. Consequently, analysis time could be reduced up to 14.2% of the necessary time to perform the complete separation allowing saving both solvents and time, which are related to a reduction of both the costs per analysis and environmental impact.
  • Keywords
    HPLC-DAD , Residual bilinearization , Beverages samples , DYES , Multivariate curve resolution alternating least squares , Second order advantage
  • Journal title
    Journal of Chromatography A
  • Serial Year
    2009
  • Journal title
    Journal of Chromatography A
  • Record number