• Title of article

    On-line solid-phase extraction of large-volume injections coupled to liquid chromatography-tandem mass spectrometry for the quantitation and confirmation of 14 selected trace organic contaminants in drinking and surface water

  • Author/Authors

    Garcia-Ac، نويسنده , , Araceli and Segura، نويسنده , , Pedro A. and Viglino، نويسنده , , Liza and Fürtِs، نويسنده , , Alexandra and Gagnon، نويسنده , , Christian and Prévost، نويسنده , , Michèle and Sauvé، نويسنده , , Sébastien، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    10
  • From page
    8518
  • To page
    8527
  • Abstract
    We describe the development and validation of an on-line solid-phase extraction of large-volume injections coupled to liquid chromatography-tandem mass spectrometry method for the simultaneous quantitation and confirmation of 14 selected trace organic contaminants in drinking and surface water. Selected compounds were: anti-infectives (clarithromycin, sulfamethoxazole and trimethoprim), an anticonvulsant (carbamazepine) and its transformation product 10,11-dihydrocarbamazepine, an antihypertensive (enalapril), antineoplastics (cyclophosphamide and methotrexate), herbicides (atrazine, cyanazine, and simazine) and two of their transformation products (deethylatrazine and deisopropylatrazine) and an antiseptic (triclocarban). The breakthrough volume determinations showed that out of all the investigated sorbents, the Strata-X on-line solid-phase extraction column showed the best performance. The method used a load volume of 10.0 mL and was validated using the corresponding matrices, yielding for most compounds, R2 > 0.99. Extraction recoveries ranged from 60 to 109%. The intra- and inter-day precision were <14 and <16%, respectively. The method detection limits ranged from 0.6 to 6 ng L−1. Matrix effects were in general low. The performance of the on-line method was demonstrated with the analysis of real water samples. The application of alternative techniques of confirmation was also explored using accurate mass measurements on a time-of-flight mass spectrometer and the data-dependent reverse energy ramp scan on a triple quadrupole.
  • Keywords
    On-line solid-phase extraction , LC–MS/MS , pesticides , Drinking water , Surface water , Pharmaceuticals and personal care products , LC-TOFMS , Emerging contaminants
  • Journal title
    Journal of Chromatography A
  • Serial Year
    2009
  • Journal title
    Journal of Chromatography A
  • Record number

    1512579