Title of article :
Utilization of a benzyl functionalized polymeric ionic liquid for the sensitive determination of polycyclic aromatic hydrocarbons; parabens and alkylphenols in waters using solid-phase microextraction coupled to gas chromatography–flame ionization detecti
Author/Authors :
Lَpez-Darias، نويسنده , , Jessica and Pino، نويسنده , , Verَnica and Meng، نويسنده , , Yunjing and Anderson، نويسنده , , Jared L. and Afonso، نويسنده , , Ana M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Abstract :
The functionalized polymeric ionic liquid poly(1-(4-vinylbenzyl)-3-hexadecylimidazolium bis[(trifluoromethyl)sulfonyl]imide (poly(VBHDIm+NTf2−)) has been used as successful coating in solid-phase microextraction (SPME) to determine a group of fourteen endocrine disrupting chemicals (ECDs), including polycyclic aromatic hydrocarbons (PAHs), alkylphenols, and parabens, in several water samples. The performance of the PIL fiber in direct immersion mode SPME followed by gas chromatography (GC) with flame-ionization detection (FID) is characterized with average relative recoveries higher than 96.1% from deionized waters and higher than 76.7% from drinking bottled waters, with precision values (RSD) lower than 13% for deionized waters and lower than 14% for drinking bottled waters (spiked level of 1 ng mL−1), when using an extraction time of 60 min with 20 mL of aqueous sample. Detection limits varied between 9 ng L−1 and 7 ng mL−1. A group of real water samples, including drinking waters, well waters, and swimming pool waters, have been analyzed under the optimized conditions. A comparison has also been carried out with the commercial SPME coatings: polydimethylsyloxane (PDMS) 30 μm, and polyacrylate (PA) 85 μm. The functionalized PIL fiber (∼12 μm) demonstrated to be superior to both commercial fibers for the overall group of analytes studied, in spite of its lower coating thickness. A normalized sensitivity parameter is proposed as a qualitative tool to compare among fiber materials, being higher for the poly(VBHDIm+NTf2−) coating. Furthermore, the partition coefficients of the studied analytes to the coating materials have been determined. A quantitative comparison among the partition coefficients also demonstrates the superior extraction capability of the functionalized PIL sorbent coating.
Keywords :
Ionic liquids , Polymeric ionic liquids , Solid-phase microextraction , Endocrine disrupting chemicals , Gas chromatography
Journal title :
Journal of Chromatography A
Journal title :
Journal of Chromatography A