• Title of article

    Chromatographic separation of neodymium isotopes by using chemical exchange process

  • Author/Authors

    Ismail ، نويسنده , , I.M. and Ibrahim، نويسنده , , M. and Aly، نويسنده , , H.F. and Nomura، نويسنده , , M. and Fujii، نويسنده , , Y.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    6
  • From page
    2923
  • To page
    2928
  • Abstract
    The neodymium isotope effects were investigated in Nd–malate ligand exchange system using the highly porous cation exchange resin SQS-6. The temperature of the chromatographic columns was kept constant at 50 °C by temperature controlled water passed through the columns jackets. The separation coefficient of neodymium isotopes, ɛ’s, was calculated from the isotopic ratios precisely measured by means of an ICP mass spectrometer equipped with nine collectors as ion detectors. The separation coefficient, ɛ × 105, were calculated and found to be 1.4, 4.8, 5.4, 10.6, 16.8 and 20.2 for 143Nd, 144Nd, 145Nd, 146Nd, 148Nd and 150Nd, respectively.
  • Keywords
    Neodymium isotopes , isotope separation , Malate ligand , Resin , chromatography , Ion exchange
  • Journal title
    Journal of Chromatography A
  • Serial Year
    2011
  • Journal title
    Journal of Chromatography A
  • Record number