• Title of article

    Comparison of gas chromatographic hyphenated techniques for mercury speciation analysis

  • Author/Authors

    Berzas Nevado، نويسنده , , J.J. and Rodrيguez Martيn-Doimeadios، نويسنده , , R.C. and Krupp، نويسنده , , E.M. and Guzmلn Bernardo، نويسنده , , F.J. and Rodrيguez Fariٌas، نويسنده , , N. and Jiménez Moreno، نويسنده , , M. and Wallace، نويسنده , , D. and Patiٌo Ropero، نويسنده , , M.J.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    7
  • From page
    4545
  • To page
    4551
  • Abstract
    In this study, we evaluate advantages and disadvantages of three hyphenated techniques for mercury speciation analysis in different sample matrices using gas chromatography (GC) with mass spectrometry (GC–MS), inductively coupled plasma mass spectrometry (GC–ICP-MS) and pyrolysis atomic fluorescence (GC-pyro-AFS) detection. Aqueous ethylation with NaBEt4 was required in all cases. All systems were validated with respect to precision, with repeatability and reproducibility <5% RSD, confirmed by the Snedecor F-test. All methods proved to be robust according to a Plackett–Burnham design for 7 factors and 15 experiments, and calculations were carried out using the procedures described by Youden and Steiner. In order to evaluate accuracy, certified reference materials (DORM-2 and DOLT-3) were analyzed after closed-vessel microwave extraction with tetramethylammonium hydroxide (TMAH). No statistically significant differences were found to the certified values (p = 0.05). The suitability for water samples analysis with different organic matter and chloride contents was evaluated by recovery experiments in synthetic spiked waters. Absolute detection and quantification limits were in the range of 2–6 pg for GC-pyro-AFS, 1–4 pg for GC–MS, with 0.05–0.21 pg for GC–ICP-MS showing the best limits of detection for the three systems employed. However, all systems are sufficiently sensitive for mercury speciation in environmental samples, with GC–MS and GC–ICP-MS offering isotope analysis capabilities for the use of species-specific isotope dilution analysis, and GC-pyro-AFS being the most cost effective alternative.
  • Keywords
    mass spectrometry , inductively coupled plasma mass spectrometry , Hyphenated techniques , Mercury speciation , Gas chromatography , Atomic fluorescence spectrometry
  • Journal title
    Journal of Chromatography A
  • Serial Year
    2011
  • Journal title
    Journal of Chromatography A
  • Record number

    1514217