Title of article
A general strategy for performing temperature-programming in high performance liquid chromatography—Further improvements in the accuracy of retention time predictions of segmented temperature gradients
Author/Authors
Wiese، نويسنده , , Steffen and Teutenberg، نويسنده , , Thorsten and Schmidt، نويسنده , , Torsten C. Schmidt، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
10
From page
71
To page
80
Abstract
In the present work it is shown that the linear elution strength (LES) model which was adapted from temperature-programming gas chromatography (GC) can also be employed for systematic method development in high-temperature liquid chromatography (HT-HPLC). The ability to predict isothermal retention times based on temperature-gradient as well as isothermal input data was investigated. For a small temperature interval of Δ T = 40 ° C , both approaches result in very similar predictions. Average relative errors of predicted retention times of 2.7% and 1.9% were observed for simulations based on isothermal and temperature-gradient measurements, respectively. Concurrently, it was investigated whether the accuracy of retention time predictions of segmented temperature gradients can be further improved by temperature dependent calculation of the parameter S T of the LES relationship. It was found that the accuracy of retention time predictions of multi-step temperature gradients can be improved to around 1.5%, if S T was also calculated temperature dependent. The adjusted experimental design making use of four temperature-gradient measurements was applied for systematic method development of selected food additives by high-temperature liquid chromatography. Method development was performed within a temperature interval from 40 °C to 180 °C using water as mobile phase. Two separation methods were established where selected food additives were baseline separated. In addition, a good agreement between simulation and experiment was observed, because an average relative error of predicted retention times of complex segmented temperature gradients less than 5% was observed. Finally, a schedule of recommendations to assist the practitioner during systematic method development in high-temperature liquid chromatography was established.
Keywords
Heating system , Method development , Linear elution strength model (LES) , Linear solvent strength model (LSS) , High-temperature high performance liquid chromatography (HT-HPLC) , Temperature-programming
Journal title
Journal of Chromatography A
Serial Year
2012
Journal title
Journal of Chromatography A
Record number
1514861
Link To Document