• Title of article

    Targeted metabolomic analysis of plasma samples for the diagnosis of inherited metabolic disorders

  • Author/Authors

    Jane?kov?، نويسنده , , Hana and Hron، نويسنده , , Karel and Wojtowicz، نويسنده , , Petr and Hl?dkov?، نويسنده , , Eva and Bare?ov?، نويسنده , , Anna and Friedeck?، نويسنده , , David and ??dkov?، نويسنده , , Lenka and Hornik، نويسنده , , Petr and Beh?lov?، نويسنده , , Darina and Proch?zkov?، نويسنده , , Dagmar and Vinohradsk?، نويسنده , , Hana and Pe?kov?، نويسنده , , Karol?na and Bruheim، نويسنده , , Per and، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    7
  • From page
    11
  • To page
    17
  • Abstract
    Metabolomics has become an important tool in clinical research and diagnosis of human diseases. In this work we focused on the diagnosis of inherited metabolic disorders (IMDs) in plasma samples using a targeted metabolomic approach. The plasma samples were analyzed with the flow injection analysis method. All the experiments were performed on a QTRAP 5500 tandem mass spectrometer (AB SCIEX, USA) with electrospray ionization. The compounds were measured in a multiple reaction monitoring mode. We analyzed 50 control samples and 34 samples with defects in amino acid metabolism (phenylketonuria, maple syrup urine disease, tyrosinemia I, argininemia, homocystinuria, carbamoyl phosphate synthetase deficiency, ornithine transcarbamylase deficiency, nonketotic hyperglycinemia), organic acidurias (methylmalonic aciduria, propionic aciduria, glutaric aciduria I, 3-hydroxy-3-methylglutaric aciduria, isovaleric aciduria), and mitochondrial defects (medium-chain acyl-coenzyme A dehydrogenase deficiency, carnitine palmitoyltransferase II deficiency). The controls were distinguished from the patient samples by principal component analysis and hierarchical clustering. Approximately 80% of patients were clearly detected by absolute metabolite concentrations, the sum of variance for first two principle components was in the range of 44–55%. Other patient samples were assigned due to the characteristic ratio of metabolites (the sum of variance for first two principle components 77 and 83%). This study has revealed that targeted metabolomic tools with automated and unsupervised processing can be applied for the diagnosis of various IMDs.
  • Keywords
    Flow injection analysis , Inherited metabolic disorders , Targeted metabolomics , Tandem mass spectrometry , Principal component analysis , hierarchical cluster analysis
  • Journal title
    Journal of Chromatography A
  • Serial Year
    2012
  • Journal title
    Journal of Chromatography A
  • Record number

    1514904