Title of article
A general method for the separation of triphenylphosphine oxide and reaction products using high performance countercurrent chromatography
Author/Authors
Edwards، نويسنده , , Neil A. and Fisher، نويسنده , , Gail and Harris، نويسنده , , Guy H. and Kellichan، نويسنده , , Nikki، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2014
Pages
8
From page
49
To page
56
Abstract
A standardised separation methodology was developed for the purification of crude reaction mixtures containing triphenylphosphine oxide (TPPO) using high performance countercurrent chromatography (HPCCC). A solvent system consisting of hexane/ethyl acetate/methanol/water (5:6:5:6) was used in 1 column volume elution–extrusion mode. The HPCCC methodology was compared with classical RP HPLC purification using a set of 12 representative Mitsunobu reaction mixtures. HPCCC was seen to yield a 65% increase in the average recovery of the target component whilst providing similar final target purities to those obtained by HPLC. By eliminating the need for method development for individual samples, the HPCCC methodology described within provides a simple and efficient means for the purification of the entire family of TPPO-containing reaction products.
Keywords
Impurity removal , Mitsunobu reaction , Countercurrent chromatography , Reverse phase liquid chromatography , Preparative chromatography , Triphenylphosphine oxide