Title of article :
Rapid trace analysis of alachlor in water and vegetable samples
Author/Authors :
Gabaldَn، نويسنده , , José Antonio and Cascales، نويسنده , , José Miguel and Maquieira، نويسنده , , Angel and Puchades، نويسنده , , Rosa، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Abstract :
The use of a rapid and specific (cross-reactivity<4%) enzyme-linked immunosorbent assay (ELISA) for the determination of alachlor residues in water and vegetable samples is addressed. The analytical method consists of a fast extraction procedure followed by an optimised ELISA. The detection limit was 0.44 μg l−1, with a linear range from 0.89 to 143.2 μg l−1. For alachlor extraction from water samples, different solid-phase cartridges (C18, Ph, C8 and C2) were assayed using MeOH as eluent. Extracts were diluted (1:4) with distilled water before ELISA. This procedure gave recoveries close to 100% with RSDs<14%. For vegetable samples, alachlor was extracted directly with MeOH and the extracts diluted 1:40 (v/v) with saline buffer prior to ELISA. The results obtained by the proposed procedure correlate well with the reference method (multiresidue extraction–GC–MS) for vegetable samples (r>0.85).
Keywords :
Alachlor , pesticides
Journal title :
Journal of Chromatography A
Journal title :
Journal of Chromatography A