Title of article :
Analysis of arson fire debris by low temperature dynamic headspace adsorption porous layer open tubular columns
Author/Authors :
Nichols، نويسنده , , Jessica E. and Harries، نويسنده , , Megan E. and Lovestead، نويسنده , , Tara M. and Bruno، نويسنده , , Thomas J.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
13
From page :
126
To page :
138
Abstract :
In this paper we present results of the application of PLOT-cryoadsorption (PLOT-cryo) to the analysis of ignitable liquids in fire debris. We tested ignitable liquids, broadly divided into fuels and solvents (although the majority of the results presented here were obtained with gasoline and diesel fuel) on three substrates: Douglas fir, oak plywood and Nylon carpet. We determined that PLOT-cryo allows the analyst to distinguish all of the ignitable liquids tested by use of a very rapid sampling protocol, and performs better (more recovered components, higher efficiency, lower elution solvent volumes) than a conventional purge and trap method. We also tested the effect of latency (the time period between applying the ignitable liquid and ignition), and we tested a variety of sampling times and a variety of PLOT capillary lengths. Reliable results can be obtained with sampling time periods as short as 3 min, and on PLOT capillaries as short as 20 cm. The variability of separate samples was also assessed, a study made possible by the high throughput nature of the PLOT-cryo method. We also determined that the method performs better than the conventional carbon strip method that is commonly used in fire debris analysis.
Keywords :
PLOT-cryoadsorption , Ignitable liquid , Headspace analysis , mass spectrometry , Gas chromatography , Fire debris analysis
Journal title :
Journal of Chromatography A
Serial Year :
2014
Journal title :
Journal of Chromatography A
Record number :
1516301
Link To Document :
بازگشت