Title of article :
Determination of maleic anhydride in occupational atmospheres
Author/Authors :
Pfنffli، نويسنده , , Pirkko and Hنmeilن، نويسنده , , Mervi and Kuusimنki، نويسنده , , Leea and Wirmoila، نويسنده , , Ritva، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Abstract :
Maleic anhydride has many uses in industry, but workers’ exposure to it is poorly known. Our new method allows airborne maleic anhydride to be determined with a limit of quantification of 1 μg/m3 per 12 l of air, i.e., the concentration of about 0.01 times the occupational exposure standard (0.4 mg/m3). Air samples are collected in Tenax tubes containing sodium sulfate as a drying agent. Maleic anhydride is eluted with methyl tert.-butyl ether containing 5% acetonitrile and 0.1% acetic anhydride, and determined by capillary gas chromatography with electron-capture detection without interference from generic anhydrides. The tested method suits both long-term and short-term measurements.
Keywords :
Maleic Anhydride , organic acids
Journal title :
Journal of Chromatography A
Journal title :
Journal of Chromatography A