• Title of article

    On the determination of a detector response enhancement factor for flow modulated comprehensive two-dimensional gas chromatography

  • Author/Authors

    Krup??k، نويسنده , , J?n and M?jek، نويسنده , , Pavel and Gorovenko، نويسنده , , Roman and ?p?nik، نويسنده , , Ivan and Sandra، نويسنده , , Pat and Armstrong، نويسنده , , Daniel W.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    6
  • From page
    235
  • To page
    240
  • Abstract
    Comparison of conventional one-dimensional gas chromatography (1D-GC) and comprehensive two-dimensional gas chromatography (GC × GC) shows that the detector signal in GC × GC is significantly enhanced. The value of this enhancement depends on the operating parameters, such as the modulation time and the non-modulated (1D column) and corresponding modulated (2D column) peak widths. Determination of the enhance factors in flow modulated GC × GC for separation of hydrocarbon samples using flame ionization detection (FM GC × GC-FID) was studied. A term named detector response enhance factor (DREF) has been designed to express the value of the signal enhancement. Two methods were used to calculate DREF: (i) employing 2D peak height, and (ii) using a theoretical approach. Comparison of FM GC × GC-FID and 1D-GC-FID method illustrates that the DREF increases from 10 to 33 times, in 1–6 s modulation time intervals.
  • Keywords
    Detector response enhancement factor – DREF , Calculation methods for DREF , Comprehensive two-dimensional gas chromatography , Flow modulation
  • Journal title
    Journal of Chromatography A
  • Serial Year
    2013
  • Journal title
    Journal of Chromatography A
  • Record number