Title of article :
Determination of cocaine in postmortem human liver exposed to overdose. Application of an innovative and efficient extraction/clean up procedure and gas chromatography–mass spectrometry analysis
Author/Authors :
Magalhمes، نويسنده , , Elisângela Jaqueline and Queiroz، نويسنده , , Maria Eliana Lopes Ribeiro de and Penido، نويسنده , , Marcus Luiz de Oliveira and Paiva، نويسنده , , Marco Antônio Ribeiro and Teodoro، نويسنده , , Janaيna Aparecida Reis and Augusti، نويسنده , , Rodinei and Nascentes، نويسنده , , Clésia Cristina، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Abstract :
A simple and efficient method was developed for the determination of cocaine in post-mortem samples of human liver via solid–liquid extraction with low temperature partitioning (SLE–LTP) and analysis by gas chromatography coupled to mass spectrometry (GC–MS). The extraction procedure was optimized by evaluating the influence of the following variables: pH of the extract, volume and composition of the extractor solvent, addition of a sorbent material (PSA: primary–secondary amine) and NaCl to clean up and increase the ionic strength of the extract. A bovine liver sample that was free of cocaine was used as a blank for the optimization of the SLE–LTP extraction procedure. The highest recovery was obtained when crushed bovine liver (2 g) was treated with 2 mL of ultrapure water plus 8 mL of acetonitrile at physiological pH (7.4). The results also indicated no need for using PSA and NaCl. The complete analytical procedure was validated for the following figures of merit: selectivity, lower limit of quantification (LLOQ), calibration curve, recovery, precision and accuracy (for within-run and between-run experiments), matrix effect, dilution integrity and stability. The within-run and between-run precision (at four levels) varied from 2.1% to 9.4% and from 4.0% to 17.0%, respectively. A maximum deviation of 11.62% for the within-run and between-run accuracies in relation to the nominal concentrations was observed. Moreover, the LLOQ value for cocaine was 50.0 ng g−1 whereas no significant effects were noticed in the assays of dilution integrity and stability. To assess its overall performance, the optimized method was applied to the analysis of eight human liver samples collected from individuals who died due to the abusive consumption of cocaine. Due to the existence of a significant matrix effect, a blank human liver was used to construct a matrix-matched analytical curve. The concentrations of cocaine found in these samples ranged from 333.5 to 5969 ng g−1.
Keywords :
cocaine , Sample preparation , Extraction procedure , GC–MS , Low-temperature partitioning , Liver
Journal title :
Journal of Chromatography A
Journal title :
Journal of Chromatography A