  • Abstract
    Ion chromatography was used to determine trace anionic contamination on the surface of hard disk drive components. These contaminants can have a detrimental effect on device reliability and yield. Disk drive components were soaked in deionized water and these extracts were analyzed for anions. The anions fluoride, acetate, formate, acrylate, methacrylate, chloride, nitrite, bromide, nitrate, benzoate, sulfate, oxalate, phthalate and phosphate were separated on a high-performance anion-exchange column and determined at concentrations less than 1 μg/l with suppressed conductivity detection. The extract solutions were analyzed either by injecting 1 ml or by preconcentrating 5 ml. We evaluated the performance of both methods.