Title of article :
On-column derivatization–capillary electrochromatography with o-phthalaldehyde/alkylthiol for assay of biogenic amines
Author/Authors :
Oguri، نويسنده , , Shigeyuki and Maeda، نويسنده , , Yuko and Mizusawa، نويسنده , , Aki، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
6
From page :
271
To page :
276
Abstract :
The elution behaviors of the biogenic amines, histamine (HA) and its metabolite methyl histamine (MHA), were evaluated by means of on-column derivatization (OCD)–capillary electrochromatography (CEC) which employed a monolithic octadecylsilica (ODS) capillary column (20 cm of effective length × 50 μm of inner diameter). Five kinds of alkylthiols, e.g., 2- hydroxyethylthiol (or 2-mercaptoethanol (2-ME)), ethanethiol (ET), 1-propanethiol (1-PT), 2-methyl-1-propanethiol (2-MPT) and 1-butanethiol (1-BT) were separately presented at 5 mM each in the OCD–CEC separation run buffer consisting of 60% acetonitrile in 5 mM o-phthalaldehyde (OPA)-10 mM borate buffer (pH 10). When 2-ME was present in the run buffer solution, both derivatives corresponding to HA and MHA migrated separately, but closely together through the capillary column. Replacement of 2-ME with 1-BT in the run buffer solution caused a delay in their elution profiles on the electrochromatogram and the separation between those two peaks became remarkably improved. The elution times of HA and MHA followed the increase in alkyl chain length or hydrophobicity of thiol, 1-BT > 2-MPT > 1-PT > ET > 2-ME. Performance of on-line preconcentrations of HA and MHA was also evaluated by varying the electrokinetic injection voltage from 1 kV to 8 kV. The peak area counts corresponding to HA recorded about 50 times higher when 2 kV was applied for 240 s to a 0.1 mM HA solution than when 8 kV was applied for 5 s. This method was next applied to a sample of human urine spiked with HA and MHA at levels of 0.1 μM each. Although HA and MHA peaks were not identifiable among the peaks corresponding to the materials in the urine matrix when OPA/2-ME was employed in a run buffer for the OCD–CEC, the separation and identification of their peaks became possible by replacing 2-ME with 1-BT in the run buffer solution.
Keywords :
histamine , Methyl histamine , Phthalaldehyde , Derivatization , Electrochromatography , Electrochromatography , Alkylthiols , Amines , biogenic amines
Journal title :
Journal of Chromatography A
Serial Year :
2004
Journal title :
Journal of Chromatography A
Record number :
1520628
Link To Document :
بازگشت