• Title of article

    Microfluidic lab-on-a-chip derivatization for gaseous carbonyl analysis

  • Author/Authors

    Pang، نويسنده , , Xiaobing and Lewis، نويسنده , , Alastair C. and Rَdenas-Garcيa، نويسنده , , Milagros، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    11
  • From page
    93
  • To page
    103
  • Abstract
    We present a microfluidic lab-on-a-chip derivatization technique for the analysis of gaseous carbonyl compounds using O-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine (PFBHA) as the derivatizing reagent. The novel microfluidic lab-on-a-chip derivatization technique has been developed to measure nmol per mole (ppbv) mixing ratios of gaseous carbonyl compounds, which are of particular importance to atmospheric chemistry. The technique utilised a planar glass microreactor comprising three inlets and one outlet, gas and fluid splitting and combining channels, mixing junctions, and a 2.0 m long, 620 μm internal diameter reaction microchannel. The microreactor integrated three functions, providing: (1) a gas and liquid mixer and reactor, (2) reagent heating, and (3) sample pre-concentration. The concentration of derivatization solution, the volumetric flow rates of the incoming gas sample and PFBHA solution, and the temperature of the microreactor were optimised to achieve a near real-time measurement. The enhanced phase contact area-to-volume ratio and the high heat transfer rate in the microreactor resulted in a fast and high efficiency derivatization reaction, generating an effluent stream which was ready for direct introduction to GC–MS. Good linearity was observed for eight carbonyl compounds over the measurement ranges of 1–500 ppbv when they were derivatized under optimal reaction conditions. The method detection limits (MDLs) were below 0.10 nmol mol−1 for most carbonyls in this study, which is below or close to their typical concentrations in clean ambient air. The performance of the technique was assessed by applying the methodology to the quantification of glyoxal (GLY) and methylglyoxal (MGLY) formed during isoprene photo-oxidation in an outdoor photoreactor chamber (EUPHORE). Good agreements between GLY and MGLY measurements were obtained comparing this new technique with Fourier Transform InfraRed (FTIR), which provides support for the potential effectiveness of the microfluidic technique for gaseous measurements.
  • Keywords
    GC–MS , PFBHA , carbonyl compounds , Microfluidic lab-on-a-chip , Derivatization
  • Journal title
    Journal of Chromatography A
  • Serial Year
    2013
  • Journal title
    Journal of Chromatography A
  • Record number

    1520777