Title of article
An anion-exchange chromatographic study on boron isotopic fractionation at 2 MPa at 293 K
Author/Authors
Musashi، نويسنده , , Masaaki and Matsuo، نويسنده , , Motoyuki and Oi، نويسنده , , Takao and Nomura، نويسنده , , Masao، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
6
From page
97
To page
102
Abstract
To study boron isotopic fractionation at high pressure, column chromatography operated in the breakthrough manner was performed at 2.0 MPa at 25.0 °C. The fractionation factor (S) between boron adsorbed onto strongly basic anion-exchange resin and boron in solution was obtained as 1.013, which was smaller than the values at 0.1 MPa (atmospheric pressure) found in literature. The pressure dependence of S was discussed based on the polymerization of boron in the solution and resin phases and on the occurrence of the pressure dependent isotope effect relating to the molar volume changes of boron species upon isotope substitution.
Keywords
Fractionation factor , Anion exchange resin , High-pressure column chromatography , Boron isotope effect