Title of article :
Fragments of protein A eluted during protein A affinity chromatography
Author/Authors :
Carter-Franklin، نويسنده , , Jayme N. and Victa، نويسنده , , Corazon and McDonald، نويسنده , , Paul and Fahrner، نويسنده , , Robert، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Abstract :
Protein A affinity chromatography is a common method for process scale purification of monoclonal antibodies. During protein A affinity chromatography, protein A ligand co-elutes with the antibody (commonly called leaching), which is a potential disadvantage since the leached protein A may need to be cleared for pharmaceutical antibodies. To determine the mechanism of protein A leaching and characterize the leached protein A, we fluorescently labeled the protein A ligand in situ on protein A affinity chromatography media. We found that intact protein A leaches when loading either purified antibody or unpurified antibody in harvested cell culture fluid (HCCF), and that additionally fragments of protein A leach when loading HCCF. The leaching of protein A fragments can be reduced by EDTA, suggesting that proteinases contribute to the generation of protein A fragments. We found that protein A fragments larger than about 6000 Da can be measured by enzyme linked immunosorbent assay, and that they can be more difficult to clear than whole protein A by cation-exchange chromatography.
Keywords :
Antibody , affinity chromatography , fluorescence detection , Leached protein A
Journal title :
Journal of Chromatography A
Journal title :
Journal of Chromatography A