• Title of article

    Microchip-based liquid–liquid extraction for gas-chromatography analysis of amphetamine-type stimulants in urine

  • Author/Authors

    Miyaguchi، نويسنده , , Hajime and Tokeshi، نويسنده , , Manabu and Kikutani، نويسنده , , Yoshikuni and Hibara، نويسنده , , Akihide and Inoue، نويسنده , , Hiroyuki and Kitamori، نويسنده , , Takehiko، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    6
  • From page
    105
  • To page
    110
  • Abstract
    A microchip-based liquid–liquid extraction for the gas chromatography analysis of urine for amphetamine-type stimulants has been developed. Partially modified microchannels with the capillarity restricted modification (CARM) method were employed for stabilizing the interface consisting of 1-chlorobutane and alkalized urine. Reliability of the microchip-based extraction was evaluated with respect to linearity, trueness and precision. As a practical demonstration, methoxyphenamine hydrochloride (50 mg) was administered to three healthy volunteers, and the concentration of methoxyphenamine in their urine was determined by both methods for comparison. This study showed the potential of pressure-driven microfluidics to contribute to the rapid automation analysis in forensic toxicology.
  • Keywords
    Forensic toxicology , Microfluidics , Solvent extraction , Gas chromatography , Amphetamines , urine
  • Journal title
    Journal of Chromatography A
  • Serial Year
    2006
  • Journal title
    Journal of Chromatography A
  • Record number

    1522807