Title of article :
Determination of erythromycin and related substances in commercial samples using liquid chromatography/ion trap mass spectrometry
Author/Authors :
Deubel، نويسنده , , A. and Fandiٌo، نويسنده , , A.S. and Sِrgel، نويسنده , , F. and Holzgrabe، نويسنده , , U.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
A sensitive, precise and accurate quantitative liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the measurement of erythromycin A (EA) and related substances in commercial samples was developed and validated. The samples were chromatographed on a reversed-phase column with a polar endcapping and analyzed by ion trap tandem mass spectrometry in the multiple reaction monitoring (MRM) mode using positive electrospray ionization. The method showed high recovery (≥98.82%), high sensitivity (lower limit of quantitation of 0.25 ng/mL for EA and less than 7.3 ng/mL for the related substances) and high precision (≤0.52%) as well as excellent linearity (r2 ≥ 0.991) with a run time of only 13 min. The method was successfully applied to the determination of EA and related substances in commercial samples. Moreover, using the advanced data-dependent acquisition capability of the ion trap software two new unexpected EA related substances could be detected and possible structures for these substances were postulated.
Keywords :
Erythromycin , Related substances , LC/MS/MS