• Title of article

    Direct determination of free cyanide in drinking water by ion chromatography with pulsed amperometric detection

  • Author/Authors

    Christison، نويسنده , , Terri T. and Rohrer، نويسنده , , Jeffrey S.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    9
  • From page
    31
  • To page
    39
  • Abstract
    Cyanide is a regulated contaminant in drinking water in the United States. This paper describes an ion chromatography method with pulsed amperometric detection (PAD) that directly determines free cyanide in drinking water. Samples are treated with sodium hydroxide to stabilize cyanide and with a cation-exchange cartridge to remove transition metals. Cyanide is separated by anion-exchange chromatography and detected by PAD with a waveform optimized for cyanide and used with a disposable silver working electrode. The recovery of cyanide spiked into five water samples was >80%. With an MDL of 1.0 μg/L, this method determines cyanide concentrations well below the reporting limits for free cyanide in drinking water.
  • Keywords
    Ion chromatography , Cyanide , Silver Electrode , IC-PAD , PAD , Pulsed amperometric detection
  • Journal title
    Journal of Chromatography A
  • Serial Year
    2007
  • Journal title
    Journal of Chromatography A
  • Record number

    1523268