Title of article
Direct determination of free cyanide in drinking water by ion chromatography with pulsed amperometric detection
Author/Authors
Christison، نويسنده , , Terri T. and Rohrer، نويسنده , , Jeffrey S.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
9
From page
31
To page
39
Abstract
Cyanide is a regulated contaminant in drinking water in the United States. This paper describes an ion chromatography method with pulsed amperometric detection (PAD) that directly determines free cyanide in drinking water. Samples are treated with sodium hydroxide to stabilize cyanide and with a cation-exchange cartridge to remove transition metals. Cyanide is separated by anion-exchange chromatography and detected by PAD with a waveform optimized for cyanide and used with a disposable silver working electrode. The recovery of cyanide spiked into five water samples was >80%. With an MDL of 1.0 μg/L, this method determines cyanide concentrations well below the reporting limits for free cyanide in drinking water.
Keywords
Ion chromatography , Cyanide , Silver Electrode , IC-PAD , PAD , Pulsed amperometric detection
Journal title
Journal of Chromatography A
Serial Year
2007
Journal title
Journal of Chromatography A
Record number
1523268
Link To Document