• Title of article

    Simultaneous analysis of gamma-hydroxybutyric acid and its precursors in urine using liquid chromatography–tandem mass spectrometry

  • Author/Authors

    Wood، نويسنده , , Michelle and Laloup، نويسنده , , Marleen and Samyn، نويسنده , , Nele and Morris، نويسنده , , Michael R. and de Bruijn، نويسنده , , Ernst A. and Maes، نويسنده , , Robert A. and Young، نويسنده , , Michael S. and Maes، نويسنده , , Viviane and De Boeck، نويسنده , , Gert، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    8
  • From page
    83
  • To page
    90
  • Abstract
    We have developed a rapid method that enables the simultaneous analysis of gamma-hydroxybutyrate (GHB) and its precursors, i.e. gamma-butyrolactone (GBL) and 1,4-butanediol (1,4-BD) in urine. The method comprised a simple dilution of the urine sample, followed by liquid chromatography–tandem mass spectrometry (LC–MS/MS) analysis. Chromatographic separation was achieved using an Atlantis dC18 column, eluted with a mixture of formic acid and methanol. The method was linear from 1–80 mg/L for GHB and 1,4-BD and from 1–50 mg/L for GBL. The limit of quantification was 1 mg/L for all analytes. The procedure, which has a total analysis time (including sample preparation) of less than 12 min, was fully validated and applied to the analysis of 182 authentic urine samples; the results were correlated with a previously published GC–MS procedure and revealed a low prevalence of GHB-positive samples. Since no commercial immunoassay is available for the routine screening of GHB, this simple and rapid method should prove useful to meet the current increased demand for the measurement of GHB and its precursors.
  • Keywords
    mass spectrometry , ?-hydroxybutyric acid , ?-Butyrolactone
  • Journal title
    Journal of Chromatography A
  • Serial Year
    2004
  • Journal title
    Journal of Chromatography A
  • Record number

    1523576