Title of article :
High precision procedure for determination of selected herbicides and their degradation products in drinking water by solid-phase extraction and gas chromatography–mass spectrometry
Author/Authors :
Auersperger، نويسنده , , Primo? and Lah، نويسنده , , Karin and Kus، نويسنده , , Jurij and Marsel، نويسنده , , Jo?e، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
8
From page :
234
To page :
241
Abstract :
For target monitoring of selected herbicides in groundwater transport studies, a precise and accurate method for the determination of atrazine (ATR), desethylatrazine (DEAT) and 2,6-dichlorobenzamide (BAM) was developed. The method is based on solid-phase extraction and GC–MS analysis. Deuterated standards are used as surrogates for calibration by the overall procedure. For legal requirements the method described was validated and is regularly subject to external quality control. Typical limits of detection are 2 ng/l. Uncertainty contributions were evaluated using the GUM workbench modelling software. At the concentration level of interest (100 ng/l), an expanded uncertainty of no more than 10% was estimated. Accurate data on the distribution of ATR, DEAT and BAM in affected well fields enabled operational changes to be implemented to control the drinking water supply according to legal requirements.
Keywords :
GC–MS , Surrogates , Deuterated standards , groundwater , 6-Dichlorobenzamide , 2 , pesticides
Journal title :
Journal of Chromatography A
Serial Year :
2005
Journal title :
Journal of Chromatography A
Record number :
1524328
Link To Document :
بازگشت