Title of article :
Determination of ethephon residues in water by gas chromatography with cubic mass spectrometry after ion-exchange purification and derivatisation with N-(tert-butyldimethylsilyl)-N-methyltrifluoroacetamide
Author/Authors :
Royer، نويسنده , , A. and Laporte، نويسنده , , F. and Bouchonnet، نويسنده , , S. and Communal، نويسنده , , P.-Y.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
An analytical method has been developed for the determination of residues of ethephon (2-chloroethyl phosphonic acid) in drinking and surface water. The procedure is based on de-ionisation with an anion/cation-exchange resin, solid phase extraction by means of anion-exchange polystyrene-divinylbenzene extraction disks, elution with a mixture of methanol and 10 M hydrochloric acid (98/2, v/v), redisolution into acetonitrile after evaporation and silylation with N-(tert-butyldimethylsilyl)-N-methyltrifluoroacetamide (MTBSTFA). Quantification is performed by gas chromatography with ion-trap cubic mass spectrometric detection in the electron impact mode (GC–EI–MS3). Method validation was conducted using samples of mineral, tap, and river water that were fortified with ethephon at concentration levels ranging from 0.1 to 1.0 μg/L. The mean recovery from all the fortified samples (n = 36) amounted to 88% with a relative standard deviation of 17%. The method, therefore, was shown to allow accurate determination of ethephon residues in drinking and surface water with a limit of quantification of 0.1 μg/L.
Keywords :
ethephon , water , GC–EI–MS3 , ion-exchange resins , Derivatisation
Journal title :
Journal of Chromatography A
Journal title :
Journal of Chromatography A