Title of article
Direct measurement of homovanillic, vanillylmandelic and 5-hydroxyindoleacetic acids in urine by capillary electrophoresis
Author/Authors
Garc??a، نويسنده , , A and Hein?nen، نويسنده , , M and Jiménez، نويسنده , , L.M and Barbas، نويسنده , , C، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2000
Pages
10
From page
341
To page
350
Abstract
Separation conditions in CE, with a neutral coated capillary and reversed polarity, have been optimised to make direct measurement of vanillylmandelic acid, homovanillic acid and 5-hydroxyindoleacetic acid possible in urine samples without pre-treatment. The method developed has been validated, presenting adequate parameters for linearity, accuracy and precision. Detection limits range from 0.03 to 2.5 μM. Finally the method has been applied to urine samples taken from patients, both adults and children, in hospital. Some of them were also measured by immunoassay and HPLC–electrochemical detection and results have been compared.
Keywords
organic acids , catecholamines , Hydroxyindoleacetic acid , Homovanillic acid , vanillylmandelic acid
Journal title
Journal of Chromatography A
Serial Year
2000
Journal title
Journal of Chromatography A
Record number
1527037
Link To Document