Title of article
Procedures and applications to enlarge the level 1+ PSA to internal fires in German nuclear power plants
Author/Authors
Berg، نويسنده , , H.P. and Breiling، نويسنده , , G. G. Hoffmann، نويسنده , , H.H.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1997
Pages
9
From page
109
To page
117
Abstract
Investigations have shown that the consequences from fires in nuclear power plants can be significant. Methodologies considering fire in probabilistic safety analyses have been evolving in the last few years. In order to provide a basis for further discussions on benefits and limits of such an analysis in Germany, current methods are investigated. As a result a qualitative screening process is proposed to identify critical fire zones followed by a quantitative event tree analysis in which the fire caused frequency of initiating events and different core damage states will be determined. The models and data proposed for a probabilistic fire risk analysis have been successfully applied in complete and partial fire risk assessments in German nuclear power plants.
Journal title
Reliability Engineering and System Safety
Serial Year
1997
Journal title
Reliability Engineering and System Safety
Record number
1570534