Title of article :
Loading adjustment policy of a two-unit shared-load system based on reliability management
Author/Authors :
Wang، نويسنده , , K.S. and Huang، نويسنده , , J.J. and Po، نويسنده , , H.J.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1998
Pages :
8
From page :
205
To page :
212
Abstract :
The expected life of a shared-load system can be extended if the adjustment of loads is allowed. In this paper, this goal is achieved by keeping the systemʹs reliability always in the maximum situation during its service. A design example of a two-column supporting system is used to demonstrate this idea. Two kinds of materials, 316-SS and CrMo, are considered. The thermal environments of the columns are different, one is 568°C and the other 501°C. Material creep phenomenon dominates the strength decay which follows the Manson-Haferd model. The results show that the expected life of the optimal load-adjusting case is approximately four times that of the averaging-load case. The numerical example also investigates the variations of one unit survival probabilities and it shows that the columns fail almost at the same time for different loading situations, but it is still at a very low level when the optimal-load adjustment is made. This indicates that the optimal loading situation gets inside the spirit of the design principle, even at the operation time beyond the systemʹs expected life.
Journal title :
Reliability Engineering and System Safety
Serial Year :
1998
Journal title :
Reliability Engineering and System Safety
Record number :
1570658
Link To Document :
بازگشت