Title of article :
Pressure and temperature analyses using GOTHIC for Mark I containment of the Chinshan Nuclear Power Plant
Author/Authors :
Chen، نويسنده , , Yen-Shu and Yuann، نويسنده , , Yng-Ruey and Dai، نويسنده , , Liang-Che and Lin، نويسنده , , Yon-Pon، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Abstract :
Chinshan Nuclear Power Plant in Taiwan is a GE-designed twin-unit BWR/4 plant with original licensed thermal power (OLTP) of 1775 MWt for each unit. Recently, the Stretch Power Uprate (SPU) program for the Chinshan plant is being conducted to uprate the core thermal power to 1858 MWt (104.66% OLTP). In this study, the Chinshan Mark I containment pressure/temperature responses during LOCA at 105% OLTP (104.66% OLTP + 0.34% OLTP power uncertainty = 105% OLTP) are analyzed using the containment thermal-hydraulic program GOTHIC. Three kinds of LOCA (Loss of Coolant Accident) scenarios are investigated: Recirculation Line Break (RCLB), Main Steam Line Break (MSLB), and Feedwater Line Break (FWLB). In the short-term analyses, blowdown data generated by RELAP5 transient analyses are provided as boundary conditions to the GOTHIC containment model. The calculated peak drywell pressure and temperature in the RCLB event are 217.2 kPaG and 137.1 °C, respectively, which are close to the original FSAR results (219.2 kPaG and 138.4 °C). Additionally, the peak drywell temperature of 155.3 °C calculated by MSLB is presented in this study. To obtain the peak suppression pool temperature, a long-term RCLB analysis is performed using a simplified RPV (Reactor Pressure Vessel) volume to calculate blowdown flow rate. One RHR (Residual Heat Removal) heat exchanger is assumed to be inoperable for suppression pool cooling mode. The calculated peak suppression pool temperature is 93.2 °C, which is below the pool temperature used for evaluating the net positive suction head of pumps of the RHR system and the Emergency Core Cooling Systems (96.7 °C). The peak containment pressure and temperature are well below the design value (386.1 kPaG and 171.1 °C). Containment integrity of Chinshan Plant can be maintained under the SPU condition.
Journal title :
Nuclear Engineering and Design Eslah
Journal title :
Nuclear Engineering and Design Eslah