Title of article :
Evaluation of precipitates used in strainer head loss testing: Part III. Long-term aluminum hydroxide precipitation tests in borated water
Author/Authors :
Bahn، نويسنده , , Chi Bum and Kasza، نويسنده , , Ken E. and Shack، نويسنده , , William J. and Natesan، نويسنده , , Ken and Klein، نويسنده , , Paul، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
12
From page :
1914
To page :
1925
Abstract :
Long-term aluminum (Al) hydroxide precipitation tests were conducted in slightly alkaline solutions containing 2500 ppm boron. The solution temperature was cycled to obtain a temperature history more representative of emergency core cooling system temperatures after a loss-of-coolant accident. The observed Al precipitation boundary was close to predicted results for amorphous precipitates, which are higher than the solubility expected for crystalline forms. Bench-scale and loop head loss test results under various conditions were successfully combined into single map in a temperature – ‘pH + p[Al]T’ domain, which yielded two bounding lines for Al hydroxide solubility in borated alkaline water that depend on whether or not loop head loss tests with Al alloy coupons are included. Precipitates were observed to form either as fine, cloudy suspensions, which showed very little tendency to settle, or as flocculated precipitates. The flocculation tendency of the precipitates can be qualitatively explained by a colloid stability theory or a phase diagram for protein solutions.
Journal title :
Nuclear Engineering and Design Eslah
Serial Year :
2011
Journal title :
Nuclear Engineering and Design Eslah
Record number :
1590830
Link To Document :
بازگشت