Title of article :
Erratum to “Experimental study on the air/water counter-current flow limitation in a model of the hot leg of a pressurized water reactor”
Author/Authors :
Deendarlianto and Vallée، نويسنده , , Christophe and Lucas، نويسنده , , Dirk and Beyer، نويسنده , , Matthias and Pietruske، نويسنده , , Heiko and Carl، نويسنده , , Helmar، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
14
From page :
3359
To page :
3372
Abstract :
This paper replaces the paper published in the journal by Deendarlianto et al. (2008). Because of an error in the implementation of the air flow meter some of the data given by Deendarlianto et al. (2008) are wrong. They are corrected within the present paper. The general results and conclusions remain unchanged. erimental investigation on the air/water counter-current two-phase flow in a horizontal rectangular channel connected to an inclined riser has been conducted. This test-section representing a model of the hot leg of a pressurized water reactor is mounted between two separators in a pressurized experimental vessel. The cross-section and length of the horizontal part of the test-section are (0.25 m × 0.05 m) and 2.59 m, respectively, whereas the inclination angle of the riser is 50°. The flow was captured by a high speed camera in the bended region of the hot leg, delivering a detailed view of the stratified interface as well as of dispersed structures like bubbles and droplets. Counter-current flow limitation (CCFL), or the onset of flooding, was found by analyzing the water levels measured in the separators. The counter-current flow limitation is defined as the maximum air mass flow rate at which the discharged water mass flow rate is equal to the inlet water mass flow rate. he high-speed observations it was found that the initiation of flooding coincides with the formation of slug flow. Furthermore, a slight hysteresis was noticed between flooding and deflooding. The CCFL data was compared with similar experiments and empirical correlations available in the literature. Therefore, the Wallis-parameter was calculated for the rectangular cross-sections by using the channel height as length, instead of the diameter. The agreement of the CCFL curve is good, but the zero liquid penetration was found at lower values of the Wallis parameter than in most of the previous work. This deviation can be attributed to the special rectangular geometry of the hot leg model of HZDR, since the other investigations were done for pipes.
Journal title :
Nuclear Engineering and Design Eslah
Serial Year :
2011
Journal title :
Nuclear Engineering and Design Eslah
Record number :
1591221
Link To Document :
بازگشت