Author/Authors :
Gnanadhas، نويسنده , , Lydia and Sharma، نويسنده , , Anil Kumar and Malarvizhi، نويسنده , , B. and Murthy، نويسنده , , S.S. and Hemanth Rao، نويسنده , , E. and Kumaresan، نويسنده , , M. and Ramesh، نويسنده , , S.S. and Harvey، نويسنده , , J. and Nashine، نويسنده , , B.K. and Chellapandi، نويسنده , , P. and Chetal، نويسنده , , S.C.، نويسنده ,
Abstract :
In fast reactor safety post accident heat removal assessment assumes importance to ensure integrity of the structural components. It is essential to demonstrate the passive built-in heat removal capabilities of the reactor in the event of a core disruptive accident. This paper details the commissioning aspect of Post Accident Thermal Hydraulics (PATH) experimental facility that is a scaled 1:4 water model of Prototype Fast Breeder Reactor (PFBR) India, to investigate heat removal by the natural convection with water as working fluid. This paper presents experimental temperature mapping and numerical methodology to evolve transient response of the system. Preliminary commissioning results for a case of 12 kW heat source is highlighted.