Title of article
Passive Containment Cooling System (PCCS) response with Drywell Gas Recirculation System (DGRS) activated during a severe accident scenario with release of non-condensable gas
Author/Authors
Paladino، نويسنده , , Domenico and Dreier، نويسنده , , Jِrg، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
9
From page
212
To page
220
Abstract
The paper presents the experimental results of an integral containment test named T2.1 performed in the PANDA facility. Test T2.1 investigated the effect of a Drywell Gas Recirculation System (DGRS) activation on a Passive Containment Cooling System (PCCS), during a postulated severe accident with release of hydrogen later during the transient (in PANDA facility Helium is used to simulate hydrogen). The containment initial thermal-hydraulic conditions (e.g. temperature, pressure, gas composition, decay heat, etc.) in test T2.1 represent the situation predicted at 1 h after a Loss of Coolant Accident (LOCA) for a specific ESBWR design. Test T2.1 simulated the decay heat which would be released during a transient of about 12.5 h, including structural heat release in the early phase. Test T2.1 includes four main phases. The first phase, lasting for about 10,000 s simulated a LOCA 1 h after SCRAM. The second phase, helium was injected for about 7200 s and the DGRS was activated. The third phase was carried on from 17,200 s to about 43,200 s by keeping the DGRS in operation. In the fourth phase the DGRS was switched off and was observed the PCCS response.
Journal title
Nuclear Engineering and Design Eslah
Serial Year
2012
Journal title
Nuclear Engineering and Design Eslah
Record number
1592198
Link To Document