Title of article
Integral transform solutions of dynamic response of a clamped–clamped pipe conveying fluid
Author/Authors
Gu، نويسنده , , Jijun and An، نويسنده , , Chen and Duan، نويسنده , , Menglan and Levi، نويسنده , , Carlos and Su، نويسنده , , Jian، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
9
From page
237
To page
245
Abstract
Analysis of dynamic response of pipe conveying fluid is an important aspect in nuclear power plant design. In the present paper, dynamic response of a clamped–clamped pipe conveying fluid was solved by the generalized integral transform technique (GITT). The governing partial differential equation was transformed into a set of second-order ordinary differential equations which is then numerically solved by making use of the subroutine DIVPAG from IMSL Library. A thorough convergence analysis was performed to yield sets of reference results of the transverse deflection at different time and spanwise position. We found good agreement between the computed natural frequencies at mode 1–3 and those obtained by previous theoretical study. Besides, modal separation analysis was carried out and the influence of mass ratio on deflection and natural frequencies was qualitatively and quantitatively assessed.
Keywords
Fluid–structure interaction , Pipe conveying fluid , Internal fluid , Clamped–clamped pipe , Integral transform , modal analysis
Journal title
Nuclear Engineering and Design Eslah
Serial Year
2013
Journal title
Nuclear Engineering and Design Eslah
Record number
1593006
Link To Document