Title of article :
Coupled code calculation of rod withdrawal at power accident
Author/Authors :
Grgi?، نويسنده , , Davor and Ben?ik، نويسنده , , Vesna and ?adek، نويسنده , , Sini?a، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Abstract :
The rod withdrawal at power (RWAP) accident is analyzed for NPP Krško as part of activity related to possible resistance temperature detectors (RTDs) bypass removal. The RWAP accident can be departure from nucleate boiling (DNB) or overpower limiting accident depending on initial power level and rate and amount of reactivity addition. In this paper we have analyzed the response of the plant in current configuration to RWAP for different withdrawal speeds and different initial power levels. By demonstrating adequacy of current protection system we can, in the next step, quantify the influence of change in narrow range coolant temperature measurement to available safety margins. The overtemperature ΔT setpoint and its relation to local DNBR values are in center of attention. The coupled RELAP5–PARCS code was used as the calculation tool with the provision to extend the calculation to local pin-by-pin COBRA subchannel calculation for selected state points derived from main coupled code results. In the first part of the calculation methodology, point kinetics calculation is performed using standalone RELAP5 to reproduce USAR results, and in the second part, more demanding coupled code calculation is introduced.
Journal title :
Nuclear Engineering and Design Eslah
Journal title :
Nuclear Engineering and Design Eslah