Title of article
The application of polynomial chaos methods to a point kinetics model of MIPR: An Aqueous Homogeneous Reactor
Author/Authors
Cooling، نويسنده , , C.M. and Williams، نويسنده , , M.M.R. and Nygaard، نويسنده , , E.T. and Eaton، نويسنده , , M.D.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
27
From page
126
To page
152
Abstract
This paper models a conceptual Medical Isotope Production Reactor (MIPR) using a point kinetics model which is used to explore power excursions in the event of a reactivity insertion. The effect of uncertainty of key parameters is modelled using intrusive polynomial chaos. It is found that the system is stable against reactivity insertions and power excursions are all bounded and tend towards a new equilibrium state due to the negative feedbacks inherent in Aqueous Homogeneous Reactors (AHRs). The Polynomial Chaos Expansion (PCE) method is found to be much more computationally efficient than that of Monte Carlo simulation in this application.
Journal title
Nuclear Engineering and Design Eslah
Serial Year
2013
Journal title
Nuclear Engineering and Design Eslah
Record number
1593485
Link To Document